Press
Buttons
Chirp/
LED Flash
Checking
Type
Follow Programming and Test Procedure
1
Voltage
Type
A. Press two times to start the engine. Allow engine to run for more
than 10 seconds.
B. If engine starts without cranking too long or too short and runs for more
than 10 seconds, press to exit programming mode (3 chirps confirm
exit). Programming is complete.
C. If the engine shuts off before 10 seconds, press to change “low
check level” to “hi check level” (2 chirps). Repeat A/B above.
D. If the engine cranks too long or too little, press to select a different
crank duration (see chart enclosed). Repeat A/B above.
Step 3A Crank Detection Programming and Procedure
3. Elapsed Timer: This method is the easiest for installation but is not always the best method for year round
usage (Summer and Winter). To operate this method, you will program a specific time window for the remote
start to crank the engine. Battery strength, environment and the aging process of the vehicle may require the
timer to reset from time to time or season to season.
+
Engine Crank Detection Programming Explanations (continued)
Press
Buttons
Chirp/
LED Flash
Checking
Type
Follow Programming and Test Procedure
2
Tachometer
Type
A. Learn the engine idle RPM.
1. Push and release the button on the transmitter
2. Start the engine with the ignition key and allow the choke to turn off.
3. With the engine at true idle speed, press and hold the valet switch
until you hear (1) long chirp and the LED is on solid for two seconds.
3A. If you do not get a response from holding down the valet switch,
check your tach connection. It may be loose or incorrect.
4. Turn off the ignition key.
B. Press two times to start the engine. Allow engine to run for more than
10 seconds.
C. If engine starts without cranking too long, press to exit programming
mode (3 chirps confirm exit). Programming is complete.
D. If the engine cranks too long, press to change “high check level” to
“low check level” (1 chirps). Repeat B/C above.
Step 3B Crank Detection Programming and Procedure
Press
Buttons
Chirp/
LED Flash
Checking
Type
Follow Programming and Test Procedure
3
Fixed Crank
Mode
A. Press two times to start the engine. Allow engine to run for more than
10 seconds.
B. If engine starts without cranking too long or too short, press to exit
programming mode (3 chirps confirm exit). Programming is complete.
C. If the engine cranks too long or too little, press to select and different
crank duration (see chart enclosed). Repeat A/B above.
Step 3C Crank Detection Programming and Procedure
+
+