Magnadyne X9 Remote Starter User Manual


 
20
ON
OFF
3X
5X + 1X (Hold)
With the ignition switch in the OFF position, Turn the
ignition switch On - Off - On - Off - On - Off
Turn On the Ignition
3 long chirps and 3 flashes of the parking lights will confirm exit of the
programming mode.
Note: Waiting 15 seconds after the last command will also cause the
system to automatically exit the programming mode.
Step 4
Exit Programming
Alarm Feature Programming (Group 2) (continued)
Alarm Feature Programming (Group 3)
Step 1 Step 2
Before 15 seconds has passed, push and release the
valet switch 6 times holding the button down on the
6th press. Wait until 3 short chirp/beeps + 1 long
chirp/beep is heard. Release the button. You are now in
“Alarm Feature Programming (Group 3)” mode.
One Chirp Two Chirps Three Chirps Four Chirps
Button LED One Pulse LED Two Pulses LED Three Pulses LED Four Pulses
(Factory Default Setting)
Step 3
Use the transmitter buttons as illustrated to adjust the features required. Keep repressing the transmitter button
that relates to the feature you want to adjust until the correct amount of chirps/beeps is heard. Move on to the
next feature.
HC2 Brown Wire
5 Sec On - 5 Sec Off
Pulsing (+) Siren Output
HC2 Brown Wire
Constant (+) Siren Output
HC2 Brown Wire
Car Horn Type (+) Output
+
HC6 Violet/Black Wire
(-) Channel 4 Output
1 Pulse Output
HC6 Violet/Black Wire
(-) Channel 4 Output
Latched Output and Reset
with Ignition "ON"
HC6 Violet/Black Wire
(-) Channel 4 Output
Output as Long as TRX
Button is Held Down
HC6 Violet/Black Wire
(-) Channel 4 Output
Output for 15 Seconds
HC6 White Wire = 2-Step
Door Unlock Output
HC6 White Wire =
Factory Security Disarm
Signal Output
HC6 White Wire =
Dome Light Output
HC6
White Wire =
Ground Output
During Start (Crank)
HC8
White/Blue Wire =
1 Pulse Activate
HC8
White/Blue Wire =
2 Pulse Activate
HC8
White/Blue Wire =
3 Pulse Activate
HC6 Light Brown Wire =
Horn Output
HC6 Light Brown Wire =
Factory Security Rearm
Signal Output
HC6 Light Brown Wire =
Start Status (Shock Sensor
Bypass Control) Output