14
Detail drawing A: wiring diagram, RIM 200 to radome unit.
NOTE:
If you have a LRA 1000 or LRA 1500, fuse the radar unit's large
white wire (+) with the supplied 5-amp fuse. If your unit is a LRA
2000, fuse the radar unit's large white wire (+) with the supplied 8-
amp fuse.
Large black/pwr –
……………… Shield/Small black ………………..
Large white/pwr + ( fuse)
Radar motor power {
……………. SW2+/Green/+V SW2 ……………..
….. SW1 On Signal/Blue/On Signal SW1 …….
…………. Data In +/Orange/Data Out + ……….
…………. Data In –/Yellow/Data Out – ……...…
……………Data Out
/
Red/Data In
…………..
…………Data Out +/Brown/Data In + ………….
To
r
adar unit
Detail Drawing A
To RIM 200