11.30
Section 11
Reassembly
Install Air Cleaner Base
1. Install a new air cleaner base gasket onto the
carburetor studs.
2. Install the air cleaner base onto the carburetor
studs. Attach the clip around the fuel line onto the
right side stud and install the two hex. flange nuts
onto the studs to secure. Torque the nuts to
9.9 N·m (88 in. lb.).
3. Connect the breather hose to the port fitting of the
air cleaner base and secure with the clamp.
4. Install the air cleaner element onto the base and
secure in place with the retainer strap. See Figure
11-101.
Install Fuel Pump
1. Mount the fuel pump, with the lines attached, onto
the blower housing, using the two hex. flange
screws. Torque the screws to 2.3 N·m (20 in. lb.).
See Figure 11-99.
Figure 11-101. Completed Installation of Air
Cleaner Parts.
5. Install the serviced precleaner around the
air cleaner element, outside of the retainer.
Completed installation is shown in Figure 11-101.
Recheck Governor Linkage Setting
1. Unhook the dampening spring and throttle linkage
from the governor arm. Remove the black
bushing.
2. Move the governor lever towards the carburetor
as far as it will move and hold in position. Do not
apply any extra pressure. Pivot the throttle linkage
to the ‘‘full throttle’’ position.
3. Check how the end of the linkage aligns with the
hole in the lever. The end of the linkage should be
in the center of the hole. See Figure 11-102. If it is
not the governor lever must be readjusted.
Figure 11-100. Hose Connected with Clip Loose.
Figure 11-99. Fuel Pump Mounting.
2. Slide the retaining clip (if removed previously) with
the loop down and out, onto the fuel pump outlet
hose for mounting later. Attach the outlet hose
from the pump to the carburetor inlet, and the
pulse hose to the crankcase fitting. See Figure
11-100. Secure on each end with the respective
clamp. Connect the inlet line (with the fuel filter)
after reassembly is completed.