Furuno FR-8062, FR-8122, FR-8252 Radar Detector User Manual


 
1. OPERATIONAL OVERVIEW
1-33
1.24.9 Restarting trails
When the range is changed while the trail feature is active, trails within the former range scale may
stopped and restarted. The relationship between trail restart and trail copy is shown in the table
below.
1. Press the MENU key to open the menu.
2. Choose Restart and press the ENTER key.
3. Choose Off or On as appropriate and press the ENTER key.
4. Press the MENU key to close the menu.
1.24.10 Trail length
Several preset trail lengths (times) are programmed for the TRAILS key for your convenience.
Standard trail times: 15 s, 30 s, 1 min, 3 min, 6 min, 15 min, 30 min, continuous
12H and 24 times: Long trail settings, continuous
If you prefer a different time you may set it as below.
1. Press the MENU key to open the menu.
2. Choose Target Trails and press the ENTER key.
3. Choose Length and press the ENTER key.
4. Choose Normal, 12H or 24H as appropriate and press the ENTER key.
Normal: Use times programmed for the TRAILS key.
12H: Continuous trail from 30 minutes to 12 hours, in increments of 30 minutes.
24H: Continuous trail from one hour to 24 hours, in increments of one hour.
For Normal, go to step 7. For 12H or 24H, go to the next step.
Restart feature Trail copy feature Action
Off On or Off Range switched to adjacent range scale
All trails are erased when range is changed. Trails are
not restarted.
Return to previous range scale
Previous trails are displayed and are continued.
On On Range switched to adjacent range scale
Previous trails remain on the display and are con-
tinued.
Return to previous range scale
Previous trails are displayed and are continued.
Off Range switched to adjacent range scale
Trails are restarted.
Return to previous range scale
Trails are restarted.
Normal
12H
24H