Ready Remote 24927 Remote Starter User Manual


 
43
© 2006 Directed Electronics
Feature Menu 2 Chart
Feature Menu 2 Descriptions
1. Arming Type: Selects if the alarm will arm by one or both avail-
able methods.
1. Active: The alarm will arm via transmitter only
2. Passive: The alarm will arm via transmitter and Passive
Arming criteria.
2. Locking Type: Selects the type of arming operations the door
locks will activate with.
1. Active: The doors will lock when armed via transmitter
and Auto Re-arming.
Feature
Location
Feature Name
Option 1
(Default)
Option 2 Option 3
1 Arming Type Active Passive NA
2
Locking Type Active Passive NA
3
Ignition Locking OFF Lock w/Ign On
/ Brake
NA
4
Ignition Unlocking OFF Unlock w/Ign
OFF
NA
5
Lock Pulses 1 2 NA
6
Unlock Pulses 1 2 NA
7
Lock Duration Short 0.8
seconds
Long 3.5
seconds
NA
8
Alarm Mode ON OFF NA
9 Auto Rearming OFF ON NA
10 Alarm Chirps ON OFF NA
11 ACC
Pulses/Domelight/St
arter kill
Accessory
Pulse (RAP)
Domelight Starter
Kill/Antigrind
Output