Dakota Digital 3X Automobile Accessories User Manual


 
MAN 650067:F
23
Oil pressure sensor test (TEST)
This menu will allow you to check the voltage the control box is reading from the pressure
sensor. This can be used for a diagnostic tool if you are having troubles or feel that the reading
is incorrect. For the Dakota Digital SEN-03-8, 0-100 psi sensor, the voltage increases with
pressure. At 0 psi, the voltage should be close to 0.5V at 100 psi the voltage should be close to
4.5V.
When “TEST” is displayed press and hold SW1 until you get “ -
Release SW1 and the current voltage or resistance from the pressure sensor will be
displayed on the speedometer and “V OIL” is displayed on the odometer readout.
Press and release SW1 to scroll through the next sensor input if you wish “R FUEL
R TEMP” “V OIL
Once complete hold SW1 until “ -” “DONE” is displayed
Release the switch to go onto the next sub-menu item.
Exit oil pressure setup (DONE)
This will allow you to exit the oil pressure setup and go on to the next setup menu.
When “Se
SeSe
Set
DONE” is displayed, press and hold SW1 until you get “ -” “DONE
Release the switch to go onto the next menu
FUEL SETUP
The control box can read seven common fuel level sender resistance values. If your
sender is not shown in the table below, the system can be programmed to read a custom
sender. The table below shows the seven pre-programmed senders and their respective empty
and full resistance values.
Sender type Menu Empty R Full R
GM 0-30 ohm (mid 60’s-earlier)
GM 30
0 ohms 30 ohms
GM 0-90 ohm (mid 60’s-late 90’s)
GM 90
0 ohms 90 ohms
GM 40-250 ohm (late 90’s-later)
GM 250
40 ohms 249 ohms
FORD 73-10 ohm (earlier -late 80’s)
F 10
73 ohms 10 ohms
FORD 20-150 ohm (late 80’s-later)
F 150
20 ohms 150 ohms
VDO 10-180 ohm
V 180
10 ohms 180 ohms
SW/SUN 33-240
SW 33
240 ohms 33 ohms
User programmed
CUSTOM
User settable
User settable
Press and hold SW 1 while turning the key on.
Release the switch and then press and release SW1 to get to the “FUEL” setup menu.
Press and hold the switch until “FUEL” is displayed to enter the fuel setup menus, then
release SW1.
Now you can press and release the switch to scroll through the fuel sub-menus, “SENDER
CUSTOM” “TEST” “DONE”.
When you get to the desired sub-menu, press and hold the switch to select it.