Baldor DTM8000 Automobile Parts User Manual


 
8
Parameter
Description
Value Range
(units)
Factory
Settings
User
Settings
0 Selecting this item exits to Running Mode n/a n/a
Read-Only Parameters
1 Model Number n/a 80
2 Software Build 1 – 9999 n/a
3 Hardware Version 1 – 9999 n/a
4 Serial Number – Major (reserved) n/a n/a
5 Serial Number – Minor (reserved) n/a n/a
General Setup
10 Operating Mode 1 – Rate Mode
2 – Time Mode
3 – Up Counter
4 – Down Counter
5 – Up / Down Counter
1
11 Display Intensity 0 – 31 (Dim – Bright) 20
14 Input Trigger / Prescaler Setup 1 - Every Rising Edge
2 – Every Falling Edge
3 – Falling Edge / 4
4 – Falling Edge / 16
1
16 Counter Mode Reset Configuration 1 – Reset Disabled
2 – Reset on Keypress
3 – Reset on S2 Low
4 – Reset on S2 High
1
Signal Input #1 (S1) Setup
20 Display Reference 1 – 9999 (Display Units) 1000
21 Reference RPM 1 – 9999 (RPM) 1000
22 Pulses Per Revolution 1 – 9999 (PPR) 10
23 Recovery Rate 0 – 1000 (1/2 seconds)
0 – Disabled
> 0 – Recovery 1/2 seconds
10
24 Display Smoothing / Averaging 0 – 60 (seconds)
0 – Disabled
> 0 – Averaging Seconds
1
25 Decimal Point Position 0 – DP Disabled (XXXX)
1 – X.XXX
2 – XX.XX
3 – XXX.X
4 – XXXX.
0
26 Auto-Ranging Configuration 0 – Auto-Ranging Off
1 – Auto-Range on Overflow
2 – Auto-Ranging On
0
27 Counter Mode Reset / Preload Value 0 – 9999 (counts) 0
30 Reserved
31 Reserved
32 Reserved
33 Reserved
34 Reserved
35 Reserved
36 Reserved
37 Counter Gate Configuration 1 – Disabled
2 – Counting Enabled (Low)
3 – Counting Enabled (High)
1
Software Parameters