Troubleshooting Messages
Display Cause Solution
AIRFLOWERROR
Fanisnotworking.Airowis
blocked.
Exit current test. Contact Robinair
authorized service center.
ANALYZERERROR1
UNSTABLEOUTPUT
1.Insufcientrefrigerantowto
identier.
2.Possibleelectromagnetic
orRF(radiofrequency)
interference.
1. Check source tank for
pressure and secure valve
connections.
2. Move unit away from EMF or
RFI sources.
ANALYZERERROR2
HIGHOUTPUT
PossibleelectromagneticorRF
(radiofrequency)interference.
Move unit away from EMF or
RFI sources.
ANALYZERERROR3
AIRCALIBRATIONLOW
Possiblerefrigerantinexternal
calibrationair.
Check air ventilation and air
ow.
ANALYZERERROR4
IDENTIFIEROUTOF
TEMPERATURERANGE
Identiertemperatureoutside
operatingrange.
Check unit ventilation and
ambient conditions.
ANALYZERERROR5
REPLACEIDENTIFIER
FILTERANDSAMPLEHOSE
ASSEMBLY
1.Insufcientrefrigerantowto
identier.
2.Samplehoseorlterinside
refrigerantidentieris
pluggedorcontaminated
withoil.
1. Check source tank for
pressure and secure valve
connections.
2.
Follow maintenance
procedure to change identier
lter and sample hose.
CHARGEINPROGRESS
AIRPURGE
Non-condensablegasis
presentinISVthatcould
contaminateA/Csystem.
Before it charges, the machine
purges air out of the ISV.
EMPTYSOURCETANK
1.Machinesenseslow
pressure.
2.Filterintankllhoseis
plugged.
1. Check source tank for
pressure and secure valve
connections.
2. Refer to Tank Fill Hose
Service in Maintenance
section.
INSUFFICIENTPRESSURE
Ifpressureislessthan0.7bar,
refrigerantcannotbeidentied.
Refer to Vacuum section; follow
instructions to evacuate system.
ISVCONDITION
Machineiscirculating
refrigeranttobuildISVpressure
forachargecycle.
Charge process is automatically
interrupted and machine
operates in a mode to build
tank pressure. Once tank
pressure is sufcient, machine
automatically completes charge.