![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/21/d2143a4f-1dc2-4dd3-abb8-5320a4f355e1/d2143a4f-1dc2-4dd3-abb8-5320a4f355e1-bgf.png)
13
AC1234-6 Rev. C
Tank Filling
Theinternalstoragevessel(ISV)maximumllofnew
refrigerantmaybeadjustedbetween1.8kgand6.8kg
byusingthekeypad.Note: The lower the ISV ll level
setting, the greater the ISV capacity for recovery.
Maximum recovery is 9.09 kg.
1. Positionthesourcetankontherearofthemachineso
liquidrefrigerantissuppliedtotheconnection.
2. UsethestrapshowninFigure3tosecurethetankin
place,beingcarefultonotblockairowfromthevents
onthelowerrightside.
3. Connectthetankllhosetothesourcetanktting,and
openthetankvalve.
4. PressOK. Themachinecheckstherefrigerantin
thesourcetanktoverifyitisR1234yfanditisnot
contaminated.Themachinedisplays
WARMUP
CALIBRATIONINPROGRESS
GASIDENTIFY
REFRIGERANTPURITYACCEPTABLE
andafterveseconds,beginsllingtheISV.Addatleast
3.6kgofrefrigeranttoensureenoughisavailablefor
charging.Thisprocesstakes15–20minutes.
5. Themachinestopswhenthedesignatedamountof
refrigeranthasbeentransferredtotheISV,orwhen
thesourcetankisempty.Followthemessagesonthe
displayscreen.
6.
PressOKtoreturntotheFunctionsMenu.Themachine
isreadyforoperation.
Note: There is no need to calibrate the scale; it was
calibrated at the factory.
Setup
Note: After the tank ll process is complete,
the display will not show the same amount
as the programmed ll level.
The display shows the amount of refrigerant
that is available for charging, which is
approximately 0.91 kg less than the total
amount of refrigerant in the tank.
WARNING: To prevent personal
injury while working with
refrigerant, read and follow the
instructions and warnings in
this manual, and wear protective
equipment such as goggles and
gloves.
Strap
Tank Fill
Hose
Figure 3
Tank Fill Adjustment
Theoperatormayeitheracceptthemachine’spre-set
defaultweightof4.5kg(10lbs.)ofrefrigerantstoredin
theISV,orchangetoalesseramounttoaccommodate
theapplication.Themaximumamountallowedfornew
refrigerantis6.8kg,whichleavesroomforadditional
recovery.
1. Themachinedisplays
4.5KG
PressOKtoacceptthedefaultamount,orusethe
keypadtoenteranamountandpressOK.
2. Themachinedisplays
CONNECTSOURCETANKTOFILLHOSE
PressOKtocontinueorESCtoexit.