![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/21/d2143a4f-1dc2-4dd3-abb8-5320a4f355e1/d2143a4f-1dc2-4dd3-abb8-5320a4f355e1-bg1b.png)
25
AC1234-6 Rev. C
Operating Instructions — System Flush
System Flushing Process
Thismachineprovidesamethodofremovingoilby
forcingliquidrefrigerantthroughanA/Csystem,or
componentsofanA/Csystem.Aspecialushing
adapter(purchasedseparately)accessestheA/C
systematthecompressorblock.Afterushing,the
refrigerantisrecoveredbythemachineandlteredby
therecyclingcircuit,returningittoSAEpuritylevels.
A/Csystemsvaryandmayrequiretheadaptingand
ushingofindividualcomponents.Refertoservice
bulletinsasneededduringthisprocedure.
Notes:
•
The machine must have at least 4.5 kg (10 lbs.) of
refrigerant available in the ISV (as indicated on the
display) for charging.
•
If the ush process is interrupted by an accidental
power-down or other fault, use the Recovery mode
to remove the refrigerant from the vehicle.
Setup
1.Verifytheoildrainbottleonthefrontofthemachine
isempty.SeeFigure10.Recoverrefrigerantas
outlinedinthismanualunderRecover Refrigerant
from a Vehicle.
2.Closeservicecouplervalvesanddisconnecthoses
fromvehicleaccessports.
3.Closethevalveontheexternalsourcetank.
Note: During this procedure, up to
4.5 kg (10 lbs.)
of refrigerant is charged into the vehicle A/C system.
If the ushing cycle is stopped before it is complete
and the external source valve is open, the machine
automatically adds refrigerant to the ISV, and there will
be no room to recover the refrigerant used for ushing.
4.RemovetheA/Csystemexpansiondevice,and
reconnectthettingstocreateabypass.
5.Disconnectthecompressorblockattherearofthe
compressor.
6.Attachthecompressorblockadapter(fromthe
ushingkit)tothesystemsideofthecompressor
block.
Figure 10
Oil Drain
Bottle
WARNING: To prevent personal
injury while working with
refrigerant, read and follow the
instructions and warnings in
this manual, and wear protective
equipment such as goggles and