4-2 Specifications and Reference Information 5707070-A
Advanced Energy
®
PHYSICAL SPECIFICATIONS
Measurement Accuracy
Accuracy Typically ± 1% to 3% of full scale
See Table 2-2 on page 2-6 for straight run requirements and
specific accuracies.
Note: Accuracy is a function of flow profile.
Linearity ± 0.5% of full scale
Repeatability ± 0.1% of full scale
Response time 1 second or less
Table 4-1. Performance specifications (Continued)
Description Specification
Table 4-2. Physical specifications
Description Specification
Electronics Enclosure
Dimensions 9.21" (H) x 7.21" (W) x 5.09" (D)
285 mm (H) x 183 mm (W) x 129 mm (D)
Note: See Figure 4-1 on page 4-6 for dimensional
illustrations.
Weight 12 lb (5.45 kg)
Materials Flame retardant, fiberglass reinforced polyester with lockable
latch, gray in color
Environmental rating NEMA 4X (IP65)
Ambient temperature
range
-13 ºF to 132 ºF (-25 ºC to 55 ºC)
Ambient humidity Less than 100% RH
Transducers
Dimensions • Transducer heads: 4.85"(L) x 1.33"(W) x 1.35"(D)
(123 mm x 33.8 mm x 34.3 mm)
• Digitizer: 4.45"(L) x 2.50" (W) x 1.10" (D)
(113 mm x 63.5 mm x 28 mm)
Note: See Figure 4-3 on page 4-8 for the dimensional
illustration