Stanley Black & Decker CT06 Automobile Parts User Manual


 
CT06 User Manual ◄ 9
HTMA REQUIREMENTS
TOOL CATEGORY
HYDRAULIC SYSTEM
REQUIREMENTS TYPE I TYPE II TYPE III TYPE RR
FLOW RATE 4–6 gpm
(15–23 lpm)
7–9 gpm
(26–34 lpm)
11–13 gpm
(42–49 lpm)
9–10.5 gpm
(34–40 lpm)
TOOL OPERATING PRESSURE
(At the power supply outlet)
2000 psi
(145–155 bar)
2000 psi
(138 bar)
2000 psi
(138 bar)
2000 psi
(138 bar)
SYSTEM RELIEF VALVE SETTING
(At the power supply outlet)
2100–2250 psi
(145–155 bar)
2100–2250 psi
(145–155 bar)
2100–2250 psi
(145–155 bar)
2200–2300 psi
(145–155 bar)
MAXIMUM BACK PRESSURE
(At tool end of the return hose)
250 psi
(17 bar)
250 psi
(17 bar)
250 psi
(17 bar)
250 psi
(17 bar)
Measured at a max. uid viscosity of:
(At min. operating temperature)
400 ssu*
(82 centistokes)
400 ssu*
(82 centistokes)
400 ssu*
(82 centistokes)
400 ssu*
(82 centistokes)
TEMPERATURE
Sufcient heat rejection capacity
to limit max. uid temperature to:
(At max. expected ambient temperature)
140 °F
(60 °C)
140 °F
(60 °C)
140 °F
(60 °C)
140 °F
(60 °C)
Min. cooling capacity
at a temperature difference of
between ambient and uid temps
3 hp
(2.24 kW)
40 °F
(22 °C)
5 hp
(3.73 kW)
40 °F
(22 °C)
7 hp
(4.47 kW)
40 °F
(22 °C)
6 hp
(5.22 kW)
40 °F
(22 °C)
NOTE:
Do not operate the tool at oil temperatures above 140 °F (60 °C). Operation at higher temperatures can cause operator
discomfort at the tool.
FILTER
Min. full-ow ltration
Sized for ow of at least:
(For cold temp. start-up and max. dirt-holding
capacity)
25 microns
30 gpm
(114 lpm)
25 microns
30 gpm
(114 lpm)
25 microns
30 gpm
(114 lpm)
25 microns
30 gpm
(114 lpm)
HYDRAULIC FLUID 100–400 ssu* 100–400 ssu* 100–400 ssu* 100–400 ssu*
Petroleum based
(Premium grade, anti-wear, non-conductive)
VISCOSITY
(At min. and max. operating temps)
(20–82 centistokes)
NOTE:
When choosing hydraulic uid, the expected oil temperature extremes that will be experienced in service determine
the most suitable temperature viscosity characteristics. Hydraulic uids with a viscosity index over 140 will meet the
requirements over a wide range of operating temperatures.
*SSU = Saybolt Seconds Universal