Seiko Group DH33 Automobile Accessories User Manual


 
English
29
Problem Possible cause Solution
The watch calculates decompression
diving even after a dive.
The diver ascended defying the
decompression stop violation warning.
When the surface interval time is less than 5 minutes, making a
decompression stop as indicated by the watch will return the
display for no-decompression diving.
**The log data stored in the dive log function will not be erased when the battery is replaced with a new one. If any malfunction is found during
checking, however, the stored log data may be erased when the watch is repaired. It is recommended that the log data in memory be noted down
in your log book before requesting a battery change.
SPECIFICATIONS
1 Frequency of crystal oscillator ... 32,768 Hz (Hz = Hertz … Cycles per
second)
2 Loss/gain (Monthly rate) ............ Less than 15 seconds at normal
temperature range (5° C ~ 35° C)
(41° F ~ 95° F)
3
Operational temperature range
... –5° C ~ +40° C (23° F ~ 104° F) for
depth measurement, alarm sound,
display and illuminating light
–10° C ~ +60° C (14° F ~ 140° F) for
timing function
* In very low temperatures, the
display light may dim, and the
change of digits may become slow.
4 Display system
TIME/CALENDAR display ..... Hour, minutes, seconds, month,
date, and day [surface interval time
and desaturation time]
REGULAR ALARM display.... Regular alarm time (hour and
minutes)
FO
2 (NITROX) display............ FO2 setting
DIVE PLAN display ............... Depth rank and no-decompression
limit [surface interval time and
desaturation time]
DIVE LOG display ................. Log No., date of dive, dive time,
entry/exit time, FO
2 setting, average
depth, maximum depth, water
temperature at maximum depth,
and residual nitrogen/oxygen at end
of dive
HOUR CORRECTION display ..
Hour and minutes
Dive mode ............................ No-decompression limit, dive time,
current depth, maximum depth,
water temperature, residual
nitrogen, FO
2 setting, current time,
PO
2 value and residual oxygen
5 Display medium ......................... Nematic Liquid Crystal, FEM (Field
Effect Mode)
6 Battery ....................................... SEIKO CR2032, 1 piece
7 Battery life ................................. Approx. 3 years
8 Illuminating light......................... Electroluminescent panel
9 Sensor accuracy......................... Depth: Within ±3% of the displayed
value + 0.5 m (2 ft)
Water temperature: ±2° C (4° F)
10
IC (Integrated Circuit) ................. C-MOS-LSI, 2 pieces
Non-volatile memory, 1 piece
* The specifications are subject to change without prior notice for product improvement.