Parker Hannifin MX80L PRECISION GRADE Automobile Parts User Manual


 
MX80L Series Product Manual Chapter 5 - Connecting the ViX Amplifier
Parker Hannifin Corporation
37
Chapter 5 - Connecting to the ViX Amplifier
The MX80L is designed to be plug and run compatible with the Parker ViX drive. The cables on
the MX80L are labeled to match the labels on the ViX for ease of use and quick installation. When
purchased as part of the part number, the ViX will have the motor parameters already downloaded.
X1 – MOTOR LEADS
WIRE COLOR DRIVE
RED U
WHITE V
BLACK W
GREEN GND
X2 – FEEDBACK-HALL CONNECTOR
PIN FUNCTION WIRE COLOR
1 Encoder Z+ ORANGE
2 Encoder Z- BROWN
3 GND BLACK
5 +5V RED
6 Temperature- YELLOW/BLACK
7 Encoder A+ WHITE
8 Encoder A- YELLOW
9 Hall#1 WHITE/BROWN
10 Temperature+ YELLOW/RED
11 Encoder B- BLUE
12 Encoder B+ GREEN
13 Hall#2 WHITE/ORANGE
14 Hall#3 WHITE/VIOLET
X5 – LIMITS CONNECTOR*
PIN FUNCTION WIRE COLOR
1 GND BLACK
6 + End of travel ORANGE
7 - End of travel BLUE
8 Home GREEN
* For Drive Only versions of the ViX, the limits need to
be connected to the motion controller NOT the drive.
Limits use Inputs
The ViX drive has 5 digital inputs. When using with MX80L, the EOT Limits and Home use 3 of the 5 inputs.
A VM15-PF screw terminal breakout board may be purchased to allow access to the remaining 2 inputs and all
of the outputs.
Daedal Division
Irwin
,
Penns
y
lvania