26
MITSUBISHI ELECTRIC
FR-F 740 EC/E1
332
RS-485 communication speed
3 / 6 / 12 / 24 / 48 / 96 / 192 / 384 96
333
RS-485 communication stop bit length
0/1/10/11 1
334
RS-485 communication parity check selection
0/1/2 2
335
RS-485 communication number of retries
0–10 / 9999 1
336
RS-485 communication check time interval
0–999.8 s / 9999 0
337
RS-485 communication waiting time setting
0–150 ms / 9999 9999
338
Communication operation command source
0/1 0
339
Communication speed command source
0/1 0
340
Communication startup mode selection
0/1/2/10/12 0
341
RS-485 communication CR/LF selection
0/1/2 1
342
Communication E
2
PROM write selection
0/1 0
343
Communication error count
—0
495
Remote output selection
0/1 0
496
Remote output data 1
ቢ
0–4095 0
497
Remote output data 2
ቢ
0–4095 0
503
Maintenance timer
0 (1–9998) 0
504
Maintenance timer alarm output set time
0–9998 / 9999 9999
549
Protocol selection
0/1 0
550
NET mode operation command source selection
0 / 1 / 9999 9999
551
PU mode operation command source selection
1/2 2
555
Current average time
ቢ
0.1–1.0 s 1 s
556
Data output mask time
ቢ
00,0–20,0 s 0 s
557
Current average value monitor signal output reference current
ቢ
0–500 A / 0–3600 A
ባ
Rated inverter current
563
Energization time carrying-over times
(0–65535) 0
564
Operating time carrying-over times
(0–65535) 0
570
Multiple rating setting
0/1 1
571
Holding time at a start
0.0–10.0 s / 9999 9999
573
4 mA Input check selection
1 / 9999 9999
575
Output interruption detection time
0–3600 s / 9999 1 s
576
Output interruption detection level
0–400 Hz 0 Hz
577
Output interruption release level
900–1100% 1000%
578
Auxiliary motor operation selection
0/1/2/3 0
579
Motor switchover selection
0/1/2/3 0
580
MC switching interlock time
0–100 s 1 s
581
Start waiting time
0–100 s 1 s
582
Auxiliary motor connection-time deceleration time
0–3600 s 1 s
583
Auxiliary motor disconnection-time acceleration time
0–3600 s / 9999 1 s
584
Auxiliary motor 1 starting frequency
0–400 Hz 50 Hz
585
Auxiliary motor 2 starting frequency
0–400 Hz 50 Hz
586
Auxiliary motor 3 starting frequency
0–400 Hz 50 Hz
587
Auxiliary motor 1 stopping frequency
0–400 Hz 0 Hz
588
Auxiliary motor 2 stopping frequency
0–400 Hz 0 Hz
589
Auxiliary motor 3 stopping frequency
0–400 Hz 0 Hz
590
Auxiliary motor start detection time
0–3600 s 5 s
591
Auxiliary motor stop detection time
0–3600 s 5 s
592
Traverse function selection
0/1/2 0
593
Maximum amplitude amount
0–25% 10%
594
Amplitude compensation amount during deceleration
0–50% 10%
595
Amplitude compensation amount during acceleration
0–50% 10%
596
Amplitude acceleration time
0.1–3600 s 5 s
597
Amplitude deceleration time
0.1–3600 s 5 s
PARAMETER