Magnadyne M10 Automobile Alarm User Manual


 
6
Optional Sensor Trigger
Ignition Trigger
Tamper Disarming:
If alarm triggered, upon disarm the system, siren chirp 4 times, parking light flash 3 times.
Pathway Illumination: (See Alarm Feature Programming Part 2-4)
This feature turns the parking light "ON" for 30 seconds upon a unlock signal and for 10 seconds
upon the lock signal.
Two Steps Door Unlock: (See Start Feature Programming Stage 1)
This feature will independently unlock the driver's door only when disarming the security
system. Pushing the ( ) button a second time within 3 seconds will unlock the entire vehicle.
Automatic Re-Arm: (See Alarm Feature Programming Part 1-3)
If this feature is selected, the security system will automatically re-arm itself 60 seconds after
disarming with remote transmitter. Automatic rearm will cancel if any door is opened before the
60 seconds timer has elapsed.
Override the Alarm:
The override function may be used if the remote transmitter is lost or inoperative.
1. Enter the vehicle and turn the ignition switch to "ON" position. (Alarm will sound).
2. Within 10 seconds push and release the valet switch. The alarm will stop sounding and enter
the disarm mode. You can now start and operate the vehicle normally.
Active Disarming (Unlock and Disarm)
Disarming Without a Transmitter
M10UM 2/20/02 12:26 PM Page 6