Furuno GP-1850F GPS Receiver User Manual


 
3-9
RETURN
EDIT
DISPLAY
SETUP2
s SPEED SOURCE GPS
TEMP SOURCE OWN XDCR
TEMP GRAPH OFF
ZOOM MARKER OFF
SPEED ADJ. +00%
TEMP ADJ. +00.0°F
DEPTH ADJ. +0.0ft
SPD
12.3kt
TEMP
62.5°F
DEPTH
2000.0ft
DGPS 3D
Figure 3-14 Display Setup 2 Display
4. Select "TEMP ADJ." by the arrow key.
5. For water temperature sensor-equipped sets, you may offset the water tem-
perature readout if it is wrong. Watch the water temperature readout at the
bottom of the screen. If it is unreasonably wrong, press the software key la-
beled "EDIT" to display the following message.
TEMP ADJ
+ 00.0 °F
Figure 3-12 Temperature Adjustment Display
6. Correct water temperature readout by the arrow key. The adjustment range is
-99.9 ~+99.9 .
For example, if the readout is 2° higher than actual temperature, enter -2°.
7. Press the software key labeled "RETURN".
8. To display a water temperature graph (shows present water temperature), se-
lect "TEMP GRAPH" by arrow key.
9. Press the software key labeled "EDIT" to display following message.
TEMP GRAPH
ON
OFF
Figure 3-13 Temperature Graph Display
10.Select "ON".
11.Press the software key labeled "ENTER".
12.Press the [SNDR] key to finish.