Emerson ATEX Automobile Parts User Manual


 
3
English
DOC.ATX.EL.1 Rev.: - May ‘03
1.3 Do
1 Keep motor compartment clean and dry.
2 When applicable connect the compartment heater.
3 Check unit wiring and ensure it coincides with the
proper wiring diagram.
4 Power supply should be free from excessive
voltage transients (spikes).
5 Control lines should be shielded properly.
6 CAUTION: Shut off incoming power before
installing or repairing any electrical device.
7 Check motor nameplate to be certain that the
actuator voltage is the same as your incoming
voltage.
8 Schedule a periodic maintenance check of all El-
O-Matic actuators to prolong life and ensure
proper performance (we suggest check for correct
opening and closing once a month).
9 Set open and close limit switches manually, in
accordance with instructions.
10 Be sure and lubricate unit during reassembly. (see
LUBRICATION)
11 Check limit switch setting prior to motor operation
if the actuator has been repaired or disassembled.
1.4 Don’t
1 CAUTION: Do not attempt to install or repair any
electric device without shutting off incoming power.
2 Do not operate valve without first setting limit
switches and checking direction of motor rotation.
3 Release torque before disassembling gear train
components or the actuator from the valve.
4 Do not adjust torque switch settings. (these are
factory set and need no adjustment)
5 Do not use a cheater or extension bar on the
handwheel. (this could result in damage to the
valve assembly or cause physical injury)
6 Do not alternately start and stop motor to seat or
un-seat a valve. f properly sized, the running
torque of the actuator should seat the valve in
normal operation.
2 Identification
Type:
U:
I:
f:
V
A
Hz
Cable compatible with a temperature
of 130˚C
II 2 G EEx d IIB T4
KEMA 03ATEX2156 X
Serial No.:
Year of manufacturing:
Manufacturer : EL-O-MATIC B.V.
7556BR, The Netherlands
EL 150
240
0.5
50
B ATEX approved execution
WARNING
* Actuator must be isolated electronically before any
(dis)assembly is begun.
* Before mounting or (dis)assembling the actuator
consult the relevant sections of this manual.
* The ATEX explosion proof certified EL electric
actuator is a Group II category 2 equipment and
intended for use in areas in which explosive
atmospheres caused by mixtures of air and gases,
vapours or mists or by air/dusts mixtures are likely
to occur.
TYPE
SERIAL No.
ELXXXX XXXXXX XXXXX
XXXXXXXXXXXXXX
WWW.EL-O-MATIC.COM
Actuator size
Power supply
specifications
Electrical entry
dimensions
Actuator size
Power supply
specifications
A Weather proof exectution