21. PRE-SET STARTER CRANKING TIME: (Requires Option #16 in “Pre-Set” Setting)
This option controls the starter cranking time when in “Timed Crank Mode. Choices are 0.5, 0.75, 1.0, or 1.5 sec.
22. DIESEL GLOW PLUG DELAY
This option controls the systems Diesel vehicle interface. Using this option you can control whether the unit
monitors the vehicles glow plug circuit using the Pink input wire (Default), or you may select a specific delay time
Before cranking. This option is helpful if you are unable to locate a glow plug signal. Just select a delay time and
do not connect the Pink Glow Plug wire. Selections: 10, 20, 30 seconds, or Monitor Pink Wire (Default).
23. REMOTE START ENGINE RUN TIME: Set engine run time for 12, 24, 36 or 48 minutes as desired.
24. ULTRA-SMART TACHLESS VOLTAGE ADJUSTMENT:
This option controls the voltage reference point when using smart Tachless mode. Pressing the Lock or Unlock
buttons on the remote raises or lowers the reference level in 1% increments from 79%-%100. Button #3 resets the
unit to the factory default reference point of 93%. The default 93% setting works for most vehicles. See page 15 for
additional Ultra-Smart Tachless mode information.
25. FACTORY HORN CHIRPS / PULSES:
This option controls the systems horn honk output. There are 3 selections:
4 Button 1 (Lock): Pulse horn when alarm is triggered.
4 Button 2 (Unlock): Pulse horn when alarm is triggered and Honk when Alarm is Armed and Disarmed.
4 Button 3 (Trunk Pop): Pulse horn when alarm is Triggered, Honk when Alarm is Armed and Disarmed and
Pulse when Shock pre-warning is set off. (default)
4 Button 4 (Start): Short Arm/Disarm Chips. Reduces the pulse from 0.04 to 0.02 seconds.
26. Aux #3: (Violet/White wire)
This option controls the function of the Violet/White wire for a negative output for a Momentary, Pulse, Timed or
Latched output, depending on option used. Option #27 controls the length of time output.
27. Aux #3 Time control: (1 sec. to 255 sec.) Default = 12 seconds
This option determines the length of time that is outputted from Aux #3 (Violet/White wire). Pressing the Lock or
Unlock buttons on the remote raises or lowers the time by one second.
28. Aux #4: (Green/White wire)
This option controls the function of the Green/White wire for a negative output for a Momentary, Pulse, Timed or
Latched output, depending on option used. Option #29 controls the length of time output.