CMC electronic MAI085MB Automobile Parts User Manual


 
mAI085-MB Actuator Interface Technical Manual /5
Distributive Intelligence
CMC INDUSTRIAL ELECTRONICS LTD
3. External Connections
1 2 3 4 9
10
V- V+G
V- V+SHD_L D_H
65
7 8
11
13
12
Figure 2 - Terminal Blocks and Connectors
ID Label Description
1 Output 1 Contact will close if in open mode or to start the conveying system.
Maximum load 1A @24VDC, 0.5A@120VAC
2 Output 2 Contact will close if in close mode or to stop the conveying system.
Maximum load 1A @24VDC, 0.5A@120VAC
3 Output 3 Contact will close if all setpoints are at zero.
Maximum load 1A @24VDC, 0.5A@120VAC
4 Output 4 Contact will close if the interface has an internal fault.
Maximum load 1A @24VDC, 0.5A@120VAC
5 Inputs 1 Energizing will select open mode.
6 Inputs 2 Energizing will select close mode.
7 Inputs 3 Energizing will clear all setpoints to zero.
8 Inputs 4 Energizing will force all actuators closed without affecting open/close
mode selection. Blending timers are ignored during a force close.