CMC electronic MAI085MB Automobile Parts User Manual


 
mAI085-MB Actuator Interface Technical Manual /28
Distributive Intelligence
CMC INDUSTRIAL ELECTRONICS LTD
Figure 6 details a typical start/stop sequence for a conveying system.
Enters Open mode
Enters Closed mode
Output 1
Actuator 1
Close Lamp
Open lamp
Output 2
Actuator 2
Acutator 3
oPL Timer expires
oDL Timer expires
Actuator 1 oDL Timer expires
Actuator 2 oDL Timer expires
Actuator 3 oDL Timer expires
Actuator 1 cDL Timer expires
Actuator 2 cDL Timer expires
Actuator 3 cDL Timer expires
cDL Timer expires
cPL Timer expires
Figure 6 - Conveying System Timing Diagram