Single Cylinder Mounted On A-Frame
1. Connect the 3/8" low pressure hose to
the outlet of the two stage regulator.
2. Attach the regulator with the “Z”
bracket on the center of the front wall
with the vent pointing down.
3. Attach the protective plastic cover to
the regulator.
4. The regulator has a 90° elbow that
directs the inlet toward the trailer
curbside.
5. Place the cylinder on the bracket
provided on the A-frame and position
is so the outlet of the cylinder valve is
pointed directly outward to the curbside wall.
6. If a vinyl cylinder cover is provided, slip it over the cylinder and leave the zipper
open.
7. Attach the 1/4" inverted flare x 24" Type 1 pigtail hose to the regulator inlet and the
right hand swivel nut to the cylinder valve.
8. If applicable, close the cylinder cover zipper up to the hose.
9. Secure the cylinder to the A-frame bracket using the bolts, nuts and washers
provided.
Double Cylinder Mounted On
A-Frame
When a second cylinder is
installed, a tee check is used to
replace the 90° elbow at the top
of the regulator and another 1/4"
inverted flare x 24" Type 1
pigtail is added. The regulator
stays in the original position.
1. Place the second cylinder on
the A-frame bracket so the
cylinder valve is pointed to
the roadside of the folding
camping trailer.
2. Secure the second cylinder
to the A-frame using the
bolts, nuts and washers
provided.
3. If a vinyl cylinder cover is
used, slip it over the new single cylinder, or a double cylinder cover may be used in
lieu of single covers.
4. Attach the second 24" hose to the tee check on the regulator and the right handed
swivel nut to the cylinder valve.
66 Jay Series/Baja/Select Folding Camping Trailer
Utilities & Systems
Flexible Pigtail Hose
Flexible Pigtail Hose
Cylinder
Valve
Cylinder
Valve
Regulator
Cylinder
Collar
Cylinder
Collar
Type 1
Acme
Connector
Type 1
Acme
Connector
Cylinder
Cylinder
Fig. 33
Cylinder
Type 1
Acme
Connector
Cylinder
Collar
Regulator
Flexible Pigtail Hose
Cylinder Valve
Fig. 32