22--1100 CCHHAANNNNEELL 44 VVAALLIIDDIITTYY//LLAATTCCHHEEDD//LLAATTCCHHEEDD RREESSEETT WWIITTHH IIGGNNIITTIIOONN//3300 SSEECCOONNDD TTIIMMEEDD//9900 SSEECCOONNDD TTIIMMEEDD
OOUUTTPPUUTT::
This wire provides a (-) 200mA output whenever the transmitter button(s) controlling Channel 4 is
pressed. This output can be programmed to provide the following types of outputs (see also the
Feature Menus
section):
VVaalliiddiittyy::
Output that will send a signal as long as the transmission is received.
LLaattcchheedd::
Output that will send a signal when the Channel 4 button(s) is pressed and will continue until the
same button(s) is pressed again.
LLaattcchheedd,, rreesseett wwiitthh iiggnniittiioonn::
Similar to the latched output, this type of output turns on the first time the
Channel 4 button(s) is pressed and turns off the next time the same button is pressed. This type of output
additionally stops and resets whenever the ignition is turned on and then off.
3300--sseeccoonndd ttiimmeedd::
Output that will send a continuous signal for 30 seconds.
9900--sseeccoonndd ttiimmeedd::
Output that will send a continuous signal for 90 seconds.
22--1
111 CCHHAANNNNEELL 55 VVAALLIIDDIITTYY//LLAATTCCHHEEDD//LLAATTCCHHEEDD RREESSEETT WWIITTHH IIGGNNIITTIIOONN//3300 SSEECCOONNDD TTIIMMEEDD//9900 SSEECCOONNDD TTIIMMEEDD
OOUUTTPPUUTT::
Channel Four can be programmed for these output configurations. The unit is set to the default valid-
ity output. To change the configuration, use the two-chirp setting to toggle through the different configurations.
Refer to channel 4 feature 2-10 for additional detail.
3
3--11 EENNGGIINNEE CCHHEECCKKIINNGG OONN//OOFFFF::
In the default setting the remote start will monitor either the vehicle's tach wire
or voltage depending on the programming of feature 3-2. If programmed OFF the vehicle will crank for the pro-
grammed crank time (feature 3-5) and will not verify with tach or voltage that the car is running. In the OFF
setting, if the vehicle fails to start, the ignition can stay on for the entire run duration. Using tach or voltage
check is always recommended if possible.
33--22 CCHHEECCKKIINNGG TTYYPPEE TTAACCHH//VVOOLLTTAAGGEE::
Selects the method of engine monitoring. If set to TACHOMETER the unit will
reference the learned tach signal to disengage the starter. In addition it will monitor the RPM and shut down if
the engine RPM is too high or too low. When set to VOLTAGE, the unit will crank the starter for the programmed
time and then attempt to sense that the engine is running by detecting an increase in voltage. The threshold
for the voltage check is selectable in feature 3-6.
33--33 RRUUNN TTIIMMEE 1122,, 2244,, 6600 MMIINNUUTTEESS::
Selects the time in minutes that the system will operate the engine
until the system "times out". This is the maximum operation period and the system may be shut down
using a shutdown at any time. Using the Bitwriter, the run time can be programmed for any duration from 1-60
minutes.