2255
rreemmoottee ssttaarrtt sseeccoonnddaarryy hhaarrnneessss ((HH33)) wwiirree ccoonn--
nneeccttiioonn gguuiiddee
This wire supplies a 200mA output as soon as the module begins the remote start process. The H3/1 BLUE wire
can also be used to activate the defogger trigger (latched/pulsed) 10-seconds after the remote start engages.
(See the
Feature Descriptions
section in this guide for details about programming this output.)
This wire MUST be connected to hood pinswitch. This input will disable or shut down the remote start when the hood
is opened. It will also trigger the security system if the hood is opened while the system is armed and report Zone 1.
This wire MUST be connected to the vehicle's brake light wire. This is the wire that shows (+) 12V when the brake
pedal is depressed. The remote start will be disabled or shut down any time the brake pedal is depressed. This
wire will also trigger the security system if the brake pedal is pressed while the system is armed and will report
Zone 1.
This input provides the module with information about the engine's revolutions per minute (RPMs). It can be
connected to the negative side of the coil in vehicles with conventional coils. In multi-coil and high energy igni-
tion systems locating a proper signal may be more difficult. (See
Finding the Wires You Need
section of this
guide.) Once connected, you must teach the system the tach signal. (See the
Internal Programming Jumpers
section of this guide.)
HH33//44 VVIIOOLLEETT//WWHHIITTEE ttaacchhoommeetteerr iinnppuutt
HH33//33 BBRROOWWNN ((++)) bbrraakkee sswwiittcchh iinnppuutt,, zzoonnee 11
HH33//22 GGRRAAYY ((--)) hhoooodd ppiinnsswwiittcchh iinnppuutt,, zzoonnee 11
HH33//11 BBLLUUEE//WWHHIITTEE ((--)) ssttaattuuss oouuttppuutt