6 PIN DOOR LOCK OUTPUT CONNECTOR: 2-STEP OPERATION
When wiring for 2-step unlock (access guard) operation, you must connect the outputs of the on-board unlock relay to the driver's
side door lock motor unlock wire. Wire these outputs as follows;
Orange = N.O. Relay Contact to +12 VDC Battery
Dark Blue = N.C. Relay Contact to Motor leg switch side
White = Common Relay Contact to Motor leg motor side
Wire the transistorized negative "alldoors unlock" output directly to the negative unlock wire fromthe door lock switch in vehicles
with 3 wire ground switched circuits.
In vehicles with 3 wire positive or 5 wire alternating switched circuits, you must add a 30 Amp automotive relay to provide the "all
doors unlock" feature.
RED w/BLACK & GREEN w/BLACK 2 PIN RED CONNECTOR: 2-STEP UNLOCK CONNECTOR
The Green w/Black tracer wire provides a 300 mA ground pulse output for the all doors unlock signal, and can be connected to the
negative door unlock wire in 3 wire negative switched vehicles.
The Red w/Black tracer wire provides a +12 VDC source for those applications that require a relay for the all doors unlock feature.
Wire the transistorized negative "alldoors unlock" output directly to the negative unlock wire fromthe door lock switch in vehicles
with 3 wire ground switched circuits.
In vehicles with 3 wire positive or 5 wire alternating switched circuits, you must add a 30 Amp automotive relay to provide the
"all doors unlock" feature.
Page 6
ANTENNAWIRE:Besuretoextendthethinblackantennawiretoitsfulllength,andcabletieintoplacewhereitcannotbedamaged.
Avoid wrapping this wire around major, high current wire looms.
WIRE DRESSING: Always wrap the alarm wiresin convoluted tubing, or with a spiral wrap of electrical tape.Secure these looms
along the routing using cable ties.
This will ensure that the alarm wires are not damaged by falling onto hot or sharp moving surfaces in the vehicle.
OPERATION:Takeafewmomentstocheckofftheappropriateoptionboxesintheowner’smanual,andtofullyexplaintheoperation