Audiovox 128-7853 Remote Starter User Manual


 
128-7853
13 of 16
13
Setting Up The System Programming Features:
Bank 1 Transmitter Channels
Start with the system disarmed, tun the ignition switch to the on position then:
1) Press and release the push button valet/program switch 3 times.
Siren Chirps once and or Lights flash one time indicating the transmitter program mode
successfully entered.
See Owners Manual for transmitter programming.
Turn the ignition switch off then on to access Bank 2 Keyless/Alarm feature selections.
1 short/1 long chirp when the key transitions off, followed by 1 short/1 long chirp when the
key is turned on indicates that you are in feature selection of bank 2.
Press the push-button switch:
1 time to access the first selection as shown below. Use the lock button of the transmitter to
change the feature selection or press the push-button to advance to the next selectable
feature.
Bank 2
Feature 1 Chirp/Flash 2 Chirp/Flash 3 Chirp/Flash 4 Chirp/Flash 5 Chirp/Flash 6 Chirps/Flash Default
1
st
Door L/UL 1 Sec. 3.5 Sec. 1 S.L, Dbl.U/L Dbl L, 1 S. UL Dbl L, Dbl UL 1S L/350ms UL 1 Sec.
2
nd
Accy Lock On Off Off
3
rd
Accy Unlock All Doors Off Off
4
th
Passive Locks Passive Active Active
5
th
Passive/Active Arm Passive Active Active
6
th
Siren/Horn Both Siren Horn Both
7
th
Horn Chirp 10ms 16ms 30ms 40ms 50ms 16ms
8
th
Override Method Custom Code Valet Valet
9
th
Chp Del From TX On Off Off
When finished setting the keyless/alarm selectable features, turn the ignition off then on to
advance to Bank 3, Remote Start Selectable Features.
No reaction when the key transitions off and 2 long Chirp when the key transitions on.
Press the push-button switch one time to access the first selection as shown below. Use the
lock button of the transmitter to change the feature selection or press the push-button to
advance to the next selectable feature.
Bank 3
Feature 1 Chirp/Flash 2 Chirp/Flash 3 Chirp/Flash 4 Chirp/Flash 5 Chirp/Flash 6 Chirps/Flash Default
1 RF Start Chirp Off On On
2 Run Time 5 Min. 10 Min. 15Min. 20 Min. 10 Min
3 Park Lights On Steady Flash Steady
4 Input Check Voltage Tach Tach
5 Voltage Level > 0.5V B4 Start < 0.5V B4 Start > 0.5
6 Ign. 2 Select Off With Crank On With Crank Same As Accy On With Crank
7 Diagnostics Off On Off
8 Crank Time 0.8Sec 1.0 Sec 1.5 Sec 2.0 Sec 1.0
9 Gas/Diesel Gas Diesel 10 Diesel 15 Diesel 20 Gas
10 Crank Averaging Averaging Preset Time Averaging
11 RS Shock Shunt Til Clear Shunt RS Cycle Shunt From Tx Shunt Til Clear
12 Turbo Select Off 3 Mins 5 Mins 10 Mins Off
13 Blk/Blue Aux O/P Single Pulse As D/L Pulse Single