Airstream 396 Automobile User Manual


 
G
PLUMBING
G - 16
FILTER REPLACEMENT
MicroTech™ replacement filter cartridges may be
purchased at the same location as the faucet. For the
dealer nearest you, call 1-800-BUY-MOEN. Use only
MicroTech filter cartridges with the PureTouch® Filter-
ing Faucet System.
Do not remove the filter until it is to be replaced.
1. Remove pullout spout (19) from receptor (15) and tie
a dishtowel around the hose to keep it from slipping
back into the spout receptor.
2. Disconnect the quarter turn, connector (18) from
pullout spout by turning it counterclockwise one-
quarter turn. Quarter turn connector will remain on
the hose.
3. Remove the filter cover by lifting up and away from
pullout spout assembly. Remove the filter by lifting
up and away from the pullout spout assemble.
NOTE: Excess water may dribble from cartridge and
valving.
4. Using soft towel or cloth, wipe excess water from
wand appliance.
5. Insert the new filter by aligning the two outlet tubes
on the filter with the two inlet ports on the spout body
and gently pressing in and down. Upon successful
installation of the filter cartridge, the pullout spout
will beep three times and the filter life indicator will
reset automatically.
6. Reinstall the filter cover by positioning the alignment
tab with the corresponding notch in the main pullout
spout body and gently pushing in and down.
7. Reattach the filtering pullout spout to the hose by
aligning the dots on the quarter turn connector (I
8) to the pullout spout (19). Push the quarter turn
connector onto the spout assembly and turn it
clockwise locking it in place.
8. Allow water to run through the new filter for 5 minutes
to flush out any loose carbon particles. After these
small black particles are washed out the filter is
ready to be used.