3FUNCTIONAL DESCRIPTION
W
EBASTO
S
CHOLASTIC
S
ERIES
3-4
3.7 7-Day Digital Timer Programming and Operating Instructions
Setting the time and
day of the week
Viewing the time
Switching heater on
for instant heater
operation
Switching the
heater off
Programming
heater-starting time
Recalling/canceling
pre-selected times
Programming
duration of
operating time
Setting the
remaining
operating time
Press the button for more than 2 seconds.
Time display flashes.
Press the or button to set time of day.
Wait 5 seconds. Time is now stored.
Day of week flashes.
Press or button to set day of week.
Wait 5 seconds. Day of week is now stored.
With ignition “ON”:
Continuous display of current time and day of the week.
With ignition “OFF”:
Briefly press button. Display of current time and weekday
appears for 5 seconds.
With ignition “ON”:
Press button. Heater is switched on (continuous heating)
and continues to operate until button is pressed again or
ignition is switched off.
With ignition “OFF”:
Press button. Heater is switched on for the preset
operating time (the factory-set heater operating duration is
60 minutes).
Press button. Heater begins cool-down (after-run) cycle
and is switched off thereafter.
Press button. Memory location number flashes.
Press or button to preset starting time.
Wait 5 seconds. Preset starting time is now stored.
Day of week flashes.
Press or button to set day of week.
Wait 5 seconds. Day of week is now stored.
The number of memory location remains on the display.
The timer is now in the programmed mode and switches
heater on at the preset time.
To recall: Press button until the desired memory location
number is displayed. Read off preset time.
To cancel: Press button repeatedly until no memory
location numbers are visible on the display.
The heater must be switched off. Press the button.
Operating time flashes.
Press or button to set operating duration time
(between 1 and 120 minutes).
Heater must be in operation.
Press button. Remaining operating time flashes.
Press or button to set remaining operating time.
Wait 5 seconds. Remaining operating time is now stored.
Table 3-1: Digital Timer Instructions