A SERVICE OF

logo

7. SERVO PARAMETERS
7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
II - 150
No. Items Details Setting range
2285 SV085
LMCk
Lost motion
compensation
spring constant
Set the machine system's spring constant when
using lost motion compensation type 3.
0 to 32767
2286
SV086
LMCc
Lost motion
compensation
viscous
coefficient
Set the machine system's viscous coefficient when
using lost motion compensation type 3.
0 to 32767
2287 SV087
FHz4
Notch filter
frequency 4
0 to 2250
(Hz)
2288 SV088
FHz5
Notch filter
frequency 5
Set the vibration frequency to suppress if machine
vibration occurs. (Valid at 141 or more) When not
using, set to "0".
To use this function, set to not "0" (normally "1")
when turning the power ON. This function cannot be
used with adaptive filter.
0 to 2250
(Hz)
2289
to
2300
Not used. Set to "0". 0