Required Maintenance
Doc 01-G0610
Rev A
Required Maintenance
Normal Usage
Check at least once every (#) of months
ITEM ACTION 1 3 6 12
Internal speed
sensor
Check for proper operation
External safety
systems
Check for proper operation
Gate caution
signs
Make sure they are present
Sprockets & pulleys Check for set screw tightness
Gate Inspect for wear or damage
Accessories Check all for proper operation
Electrical Inspect all wire connections
Frame bolts Check for tightness
Total unit Inspect for wear or damage
>
>>
>Complete Checkout <
<<
<
Table 6
CAUTION
When servicing, always disconnect operator from electrical power supply.
NOTES
Severe or high cycle usage will require
more frequent maintenance checks.
Inspection and service should always be
performed anytime a malfunction is
observed or suspected.
When servicing, please do some “house
cleaning” of the operator and the area
around the operator. Pick up any debris in
the area. Clean the operator if needed.
It is suggested to take some voltage
readings of the operator while at the site.
Using a VOM, double check the incoming
voltage to the operator to make sure it is
within ten percent of the operator’s rating.
While you are at the site, now would be a
good time to let the owner or manager
know about any new items available or
any safety items that could and should be
added to the site.