Select the type of mounting desired. The Model is designed for post mounting as factory standard, but
may either be pad mounted or pedestal mounted if provided with either the optional pad mount or
pedestal mount accessory kit.
Post Mount Installation
1 Locate mounting posts according to the
illustration on p. 12. Locate electrical
conduit.
The operator cabinet may be installed either
parallel or perpendicular to the fence with
access cover facing away from fence (see
Figure 5 or Figure 6).
2 Excavate required areas for conduit
installation and mounting posts.
3 Set mounting posts and conduit in place.
Knockouts for 3" pipe clamps (not supplied) are
in the operator.
IMPORTANT NOTE: The distance between
mounting posts and the relative location of
the operator to the gate and fence is critical.
Be sure that the measurements for operator
mounting are taken from the centerline of
the fence and of the gate hinge.
4 Pour cement to secure mounting posts and
allow to set for (2) days before installing
power unit.
5 Knock out the post mount holes on each
end of the cabinet. There are (3) sets of
holes vertically.
The preferred method of post mounting is to
use the (2) sets of holes nearest to the rear
side of the cabinet (the side with the access
cover is referred to as the front side).
If mentioned holes are used, note that the
upper rear holes are larger than the other
holes. This is because a special nut is required
for the U-Bolt in these holes due to an
inaccessibility of tools inside the cabinet in the
area of these holes.
6 Set the operator between the posts. Allow
3" ground clearance from bottom of cabinet.
When the posts are secured, the post tops
should not protrude above the top flange of the
operator. The operator should be level and
square to the gate.
7 Insert the U-Bolt Nut (80-22754) through the
cabinet wall from the inside and onto the leg
of the U-Bolt. This nut can be tightened with
a wrench from outside the cabinet.
A special tool is provided for this purpose (see
Figure 6).
8 Use standard 3/8-16 hex nuts to secure all
remaining U-Bolts.