![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/7/65/765eb686-93d0-4fc6-baa7-f2636af9bd88/765eb686-93d0-4fc6-baa7-f2636af9bd88-bg14.png)
20
Programming
Doc 01-G0610
Rev A
POLE
#1
POLE
#2
POLE
#3
POLE
#4
TOTAL TIME WARNING
DEVICE DISABLED
TOTAL TIME WARNING
DEVICE ENABLED
ON ON ON ON DISABLED DISABLED
OFF ON ON ON 1 SEC. 4 SEC.
ON OFF ON ON 13 SEC. 16 SEC.
OFF OFF ON ON 26 SEC. 2 SEC.
ON ON OFF ON 40 SEC. 43 SEC.
OFF ON OFF ON 52 SEC. 55 SEC.
ON OFF OFF ON 65 SEC. 68 SEC.
OFF OFF OFF ON 78 SEC. 81 SEC.
ON ON ON OFF 104 SEC. 107 SEC.
OFF ON ON OFF 117 SEC. 120 SEC.
ON OFF ON OFF 129 SEC. 132 SEC.
OFF OFF ON OFF 141 SEC. 144 SEC.
ON ON OFF OFF 155 SEC. 158 SEC.
OFF ON OFF OFF 167 SEC. 170 SEC.
ON OFF OFF OFF 180 SEC. 183 SEC.
OFF OFF OFF OFF 194 SEC. 197 SEC.
Table 5
Switch #2: Timer to Close
Timer to close is locked out at the factory. To activate the timer to close, follow steps below:
01-G0610F14
Figure 15
1 Move safety jumper from bottom two pins to top two pins. Then set time per the chart above
(Table 5).
2 During normal operation, if the operator stops on a limit, or mid travel, the operator will time
out per the chart below and automatically close.
3 To lock the timer to close program and disable, simply return the jumper to the bottom two
pins, or turn on all pins of SW#2.
IMPORTANT NOTE: When using master/slave, only set the time for the master operator.
The slave operator must be set to disabled position (all poles on).