A SERVICE OF

logo

108 Agilent E1441A SCPI Command Reference
Chapter 3
Parameters
FREQuency:STARt?
[SOURce:]FREQuency:STARt? [MIN|MAX] queries the start frequency. Returns a
value in hertz.
FREQuency:STOP
[SOURce:]FREQuency:STOP <frequency>|MIN|MAX sets the stop frequency.
Select from 10 mHz to 15 MHz (100 kHz for triangle and ramp). The sweep is phase
continuous over the full frequency range. The default is 1 kHz. MIN = 10 mHz.
MAX
= 15 MHz. [ Stored in volatile memory ]
Parameters
FREQuency:STOP?
[SOURce:]FREQuency:STOP? [MIN|MAX] queries the stop frequency. Returns a
value in hertz.
Frequency-Shift Keying (FSK) Commands
Use the APPLy command or the equivalent FUNC:SHAP, FREQ, VOLT, and
VOLT:OFFS commands to configure the carrier waveform. Set the carrier frequency
between 100 ยตHz and 15 MHz (100 kHz maximum for triangle and ramp). The
default is 1 kHz.
Parameter Name Parameter Type Range of Values Default Units
frequency numeric 10E-03 to 15E+06 Hz
Parameter Name Parameter Type Range of Values Default Units
frequency numeric 10E-03 to 15E+06 Hz