A SERVICE OF

logo

Appendix A
Appendix A Technical Specification A
-3
Table A-2 ADAM-4011 Range Accuracy for Thermocouple
Input
Range
Code
(Hex)
Input Range
Typical
Accuracy
Maximum
Error
Units
0E
J thermocouple
0 to760
±0.5 ±0.75
0F
K thermocouple
0 to 1370
±0.5 ±0.75
10
T thermocouple
-100 to 400
±0.5 ±0.75
11
E thermocouple
0 to 1000
±0.5 ±0.75
12
R thermocouple
500 to 1750
±0.6 ±1.5
13
S thermocouple
500 to 1750
±0.6 ±1.5
14
B thermocouple
500 to 1800
±1.2 ±2.0