40
©
2006
Directed Electronics
Nuisance Prevention
®
Circuitry
Nuisance Prevention
®
Circuitry bypasses any zone that triggers the system more than three times
within a one-hour period. For a full description of NPC
®
operations refer to the Owner's Guide.
Rapid Resume Logic
Rapid Resume Logic ensures that when the system is powered up it will return to the same state it
was in when power is disconnected. For a full description of Rapid Resume Logic refer to the
Owner's Guide.
Troubleshooting
Starter kill doesn’t work.
➤
Is the correct starter wire being interrupted? If the car starts when the starter kill relay is
completely disconnected, the wrong starter wire has been cut and interrupted. Is the NC/NO
programmed correctly?
➤
YELLOW wire is not connected to true ignition. It is connected to an accessory circuit.
Sensors don’t trigger the alarm.
➤
Has the NPC
®®
system been triggered? If so, you will hear five chirps when disarming. To check
this, turn the ignition key on and off to clear the NPC
®®
from memory, and then retest the
sensors. For a detailed description of NPC
®®
, see Owner’s Guide.
Door input does not immediately trigger full alarm. Instead, I hear chirps for the first three seconds.
➤
That’s how the progressive two-stage door input works! This is the instant response feature of
this system. Even if the door is closed immediately, the system provides an instant trigger by
chirping, and then progressing to a constant siren.
IMPORTANT: When testing the systems sensor and trigger inputs reset NPC
®
by
turning on the ignition after every third system trigger.