LT-12 SERIES LIGHT TOWER — OPERATION MANUAL — REV. #1 (08/15/08) — PAGE 29
LT-12 SERIES LIGHT TOWER — SHUTDOWN PROCEDURES
Normal Shut-down
1. If a load is attached to the generating set of the light tower,
remove the load
.
2. Set CB-1 thru CB-4 on the control panel to the OFF position.
3. Place the MAIN circuit breaker (Figure 5, Item 4) on the
control panel to the OFF position.
4. Wait a few seconds and observe that flood all floodlights
are OFF.
5. Let the engine idle for a few minutes with no load.
6. Turn the ignition key to the OFF position. Store key in a safe
location.
7. Lower light tower mast and place in stow position as outlined
in the Pre-Setup section of this manual.
8. Place outriggers in tow position, and remove chock blocks.
9. Store light tower in a clean, dry location out of the reach of
children and bystanders.
Allow flood lights to cool (15
minutes) if service or removal of
bulb is required.
NOTE
Emergency Shut-down
1. Turn the ignition key to the OFF position.