MAXFORCE BREAKER User Manual ◄ 9
PRE-OPERATION
PREPARATION FOR OPERATION
NITROGEN CHARGE
Thebreakerhasbeenproperlychargedwithnitrogenat
thefactoryandisreadytouse(seepages20and21)for
charginginformation.
TOOL BIT LUBRICATION
Greasethetop250mm/10inches ofthebreakertool
bitbefore installing.During operation,thetool canbe
greasedthroughthegreasetting.Greaseasrequired.
Make sure the tool bit is against the tool stop by
placing the tool bit against the ground and then put-
ting down pressure on the breaker. SEE THE ILLUS-
TRATION BELOW AND ON THE FOLLOWING PAGE.
ToolBit
250 mm/10 in.
GreaseThis
AreaofBit
Figure1.GreasingtheToolBitBeforeInstallation
NOTICE
Greasing the tool bit without down pressure on
the tool will result in grease lling the space
between the piston and the tool bit.
When the breaker is next activated, the piston
will strike the grease at a speed that will cause
the grease to apply great force against the seals
and grease zerk resulting in damage to these
components.
PRE-INSTALLATION INSTRUCTIONS
EXCAVATOR SIZE
ContactStanleyHydraulicToolstodeterminecorrectex-
cavatorsize.Seethe"SPECIFICATIONS"sectionofthis
manualforhydraulicowandpressurerequirements.
NOTICE
Ifhydraulicpressure,hydraulicback-pressure,
hydraulicow,orexcavatorweightclassare
exceeded,thetoolwarrantyisvoid.
EXISTING EQUIPMENT HYDRAULICS VS
APPLICATION ATTACHING KITS
Using existing equipment hydraulic auxiliary systems
foroperatinghydraulictoolscouldcauseproblemsfor
thehydraulictoolandthehydraulicsystemifnotsetup
properly.Simplypluggingintothehydraulicsystemwith-
outconrmingpressureandowtothehydraulictoolis
notagoodpractice.Sparespoolvalves,dippercircuits,
etc.,are justa fewexamples ofeasilyaccessible hy-
drauliccircuitswhichcouldprovetocauseproblemsfor
hydraulic tool usage.
ATTACHINGKITSadapttoexistinghydraulicsystems
ofmanypopularbackhoesandexcavators.
Ifyourequipmentdoesnotcontainanattachingkit,ask
your Stanley dealer for information, installation, and
pricingonakitwhichmatchesyourequipmentneeds.
TEST THE HYDRAULIC SYSTEM
1. HaveyourStanleydealertesttheexcavatorhydrau-
licsystemtomakesurethesystemisoperatingat
themanufacturersspeciedcapacityandpressure
ratings.
2. Besuretheuidinthehydraulicsystemisclean.
3. Checkthehydrauliclter.Replacethelterifdirtyor
deteriorated.
4. Haveyour Stanleydealertest thecircuitto which
thebreakerwillbeconnectedtomakesurethatthe
circuitissupplyingthespeciedowandpressure
rating for thebreaker. See the SPECIFICATIONS
sectionofthismanual.