14 ► MAXFORCE BREAKER User Manual
OPERATION
UNDERWATER USE
Nopartofthebreakermaybesubmergedinwater
unlessanairapplicationkitisused.Underwater
usageofthebreakerwithoutairapplicationwill
causeinternaldamagetothebreaker.Consult
Stanleyformodicationsandspecicwarranty
coverageifyouhaveanunderwaterrequirement.
Do not use underwater
withoutairapplicationkit
UNDERWATER USE
Figure11.UnderwaterUse
Thebreakerisequippedwithanunderwaterportonthe
sideofthebreaker.Connectanairlinetothisportand
supplytherequiredairpressureandowtothebreaker
whenusingunderwater.Thefollowingtableshowsthe
airpressurerequired.
Model Required Air
Amount
Required Air
Pressure
Compressor
Horsepower-Min
Fitting Location
on Exploded View
MBX138 0.5m³ / min 75-100 psi /5-7 bar 3.7 Kw Item # 9A
MBX208 0.5m³ / min 75-100 psi /5-7 bar 3.7 Kw Item # 9A
MBX258 1.0m³ / min 75-100 psi /5-7 bar 3.7 Kw Item # 9A
MBX308 1.0m³ / min 75-100 psi /5-7 bar 3.7 Kw Item # 9A
MBX358 1.0m³ / min 75-100 psi /5-7 bar 3.7 Kw Item # 71
MBX408 1.0m³ / min 75-100 psi /5-7 bar 3.7 Kw Item # 72A
MBX458 1.0m³ / min 75-100 psi /5-7 bar 3.7 Kw Item # 72A
MBX608 1.0m³ / min 75-100 psi /5-7 bar 3.7 Kw Item # 9A
CAUTION