10. The following message will appear: Full level Calibration Com-
pleted.
Press ENT, then press EXIT repeatedly to get back to the main
display.
Calibrate is highlighted on the device configuration menu (left). Cali-
bration menu (right) with calibration instructions listed at the top.
3-Point Calibration
3-point calibration is designed for tanks that vary in shape from the top
to the bottom. You can begin calibration at any point in the 3-point
process, but we recommend starting calibration with an empty tank.
In a 3-point calibration, you will set three points, one each for empty,
half and full levels.
1. Press
MENU| MENU, use to select NMEA 2000 and press ENT.
2. Highlight
BUS SETUP and press ENT, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page. 3.
Select the EP-15 Fluid Level and press
ENT.
4. Press to select
CALIBRATE and press ENT. The Device Calibration
menu will appear.
5. Highlight
NUM PTS, press ENT and select 3. Press ENT.
6. Make sure your tank is empty, then highlight FLUID LEVEL and press
ENT
. Select EMPTY LEVEL and press ENT.
7.
Select CALIBRATE and press ENT. The following message will appear:
Empty Level Calibration Completed. Press
ENTER.
8.
Add half a tank of fuel, highlight FLUID LEVEL and press ENT. Select
H
ALF LEVEL and press ENT.
9.
Select CALIBRATE and press ENT. The following message will appear:
Half Level Calibration Completed. Press
ENT.
10. Fill up the tank, then
highlight FLUID LEVEL and press ENT. Select
F
ULL LEVEL and press ENT.