Lowrance electronic 5300c GPS Receiver User Manual


 
142
To check fuel flow accuracy:
Select Fuel Used to be shown as Overlay Data on your unit's main dis-
play. Refer to the Overlay Data segment of this manual for instructions
on how to select Fuel Used data as Overlay Data.
1. After selecting Fuel Used as overlay data, fill up your tank and press
MENU|MENU.
2. Select
NMEA 2000 and press ENT.
3. Highlight
FUEL MANAGEMENT and press ENT. Select TANK LOCATION and
press
ENT.
4. Use to select the location (Port, Center or Starboard) of the fuel
flow you want to calibrate and press
ENT.
5. Highlight
FILL TANK and press ENT. The following confirmation mes-
sage will appear: Are you sure you wish to Fill Tank?
6. Select
YES and press ENT. The following confirmation message will
appear: Do you wish to re-calibrate the device?
7. Highlight
NO and press ENT.
8. Take your vessel out on the water and burn at least five gallons of
fuel. Be sure you run only ONE engine — the engine connected
to your fuel flow.
9. Fill up your tank again, noting how much fuel you added to the tank.
Compare that number to the Fuel Used figure displayed on the page
you customized. If the amount of fuel you added to the tank and the
fuel used figure are off by more than 3 percent, we recommend the fuel
flow be calibrated.
NOTE:
You must use the gauge's Fill Tank command when filling your fuel
tank to keep the fuel flow updated with correct information on the
amount of fuel in the tank.
To calibrate an EP-10 Fuel Flow:
10. If calibration is necessary, press MENU|MENU, select NMEA 2000 and
press
ENT.
11. Highlight
FUEL MANAGEMENT and press ENT.
12. Select
TANK LOCATION and press ENT to choose the location of the tank
connected to selected fuel flow. Press
ENT.
13. Highlight
FILL TANK and press ENT. The following message will ap-
pear: Are you sure you wish to Fill Tank? Select
YES and press ENT.
14. The following message will appear: Do you wish to re-calibrate the
device? Select
YES and press ENT.
15. Repeat these steps for each EP-10 Fuel Flow you want to calibrate.
www.Busse-Yachtshop.de email: info@busse-yachtshop.de