Reference Station
Click on POWER DOWN in the Web Interface Tools menu.
Behaviour when
turning off and on
Turning the GRX1200+ Series off and on again resets the receiver. The conse-
quences are:
If the configuration of the output is stored in the configuration set, standard
NMEA messages are still output.
All data/message outputs scheduled via OWI or LB2 commands are no longer
output.
Data logging parameters and interface configuration options, that have been set
by OWI or LB2 commands and have not been saved to a configuration set using
the corresponding OWI or LB2 command, are reset.
Behaviour after
power failure
After temporary power failure, the GRX1200+ Series will automatically power itself
up and resume the previously set operations including OWI or LB2 output. Two
power fail recovery options are available - Sudden Loss Only and Always. To
access the configuration select either:
RX1200: Main Menu: Config...\General Settings...\Start Up & Power Down.
Computer: Configuration - Start Up & Power Down in the web interface.