Kohler LV625 Automobile Parts User Manual


 
11.28
Section 11
Reassembly
3. Install the carburetor as an assembly, onto the
carburetor studs. See Figure 11-94. Carefully lift
up on the lower blower housing, directly above the
carburetor, and slide the carburetor into place
against the gasket and manifold.
3. Pivot the governor lever toward the carburetor as
far as it will move (wide-open throttle) and hold in
position.
4. Insert a nail into the hole in the cross shaft and
rotate the shaft counterclockwise as far as it will
turn, then torque the hex. nut on the clamp screw
to 9.9 N·m (88 in. lb.). See Figure 11-96. If, after
torquing, no gap exists between the metal clamp
surfaces, replace the governor lever.
Figure 11-94. Installing Carburetor.
Install External Governor Controls
1. Install the governor lever onto the governor cross
shaft. See Figure 11-95.
Figure 11-95. Installing Governor Lever onto
Governor Shaft.
2. Insert the plastic bushing clip and connect the
throttle linkage to the governor lever. Connect
the dampening spring into the adjacent hole in
the governor lever.
Figure 11-96. Torquing Governor Lever Clamp
Hardware.
5. Connect the two wire leads for the fuel shut-off
solenoid (if so equipped) to the wiring harness
leads.