308351 41
Technical Data
(Models 240945, 253376, and 198475 Quiet King Pump and
Model 237265 Reduced Icing Quiet King Pump)
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
To find Pump Air Consumption (m#/min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air consumption
curve (dashes). Follow left to scale to read air consumption.
A 0.6 MPa, 6.2 bar (90 psi) air pressure
B 0.5 MPa, 4.9 bar (70 psi) air pressure
C 0.3 MPa, 2.8 bar (40 psi) air pressure
Performance Charts
0
2000
4000
6000
0123
Fluid Outlet Pressure
21 42 63
psi
MPa, bar
cycles per minute
gpm
liters/minute
3.8 7.6 11.4
FLUID PRESSURE
42, 420
28, 280
14, 140
A
B
C
0
100
200
300
0123
Air Consumption
21 42 63
scfm
m#/min
cycles per minute
gpm
liters/minute
3.8 7.6 11.4
AIR CONSUMPTION
A
B
C
8.40
5.60
2.80
0
2000
4000
6000
0123
Fluid Outlet Pressure
21 42 63
psi
MPa, bar
cycles per minute
gpm
liters/minute
3.8 7.6 11.4
FLUID PRESSURE
42, 420
28, 280
14, 140
A
B
C
0
100
200
300
0123
Air Consumption
21 42 63
scfm
m#/min
cycles per minute
gpm
liters/minute
3.8 7.6 11.4
AIR CONSUMPTION
A
B
C
8.40
5.60
2.80
Test Fluid: No. 10 Weight Oil
Test Fluid: 4 Million CPS Weldable Rubber Base Sealer