Furuno CI-68 Radar Detector User Manual


 
2. INTERPRETING THE DISPLAYS
2-12
Tide for three layers/tide differential
(4) Depth setting error
1
2m
2.3 140
TIDE SPD/VECTOR kt
(3) Echo from measuring layer
is abnormal
2.3 140
TIDE DIFF kt
3) Echo from measuring layer
is abnormal
1 2
Tide vector, speed, graph and
course plot displays
Text and echo level displays
(4) Depth setting error
1
2m
2.3 140
TIDE SPD/VECTOR
(3) Echo from measuring layer
is abnormal
kt
2.3 140
TIDE DIFF
3) Echo from measuring layer
is abnormal
1 2
Tide vector, speed, graph and
course plot displays
Text and echo level displays
kt
Tide and tide differential error displays
(3) Displayed when echo for a measuring layer is not present. The readout for the offending
measuring layer is not reliable.
(4) Displayed when the depth setting for a measuring layer is improper. The readout for the
offending measuring layer is not reliable.
Improper depth setting conditions
Depth in ground tracking mode is less than 10 m.
Depth setting is more than 75% of actual depth.
Echo cannot be obtained because of air bubbles, etc.
Echo for set depth cannot be found because depth has become deeper than set
depth.