Stopping Trigger
Once QwikData starts logging, it must either wait for the power to be shut off, the “Stop Logging” command to be issued via the Real
Time screen, or the “Stop” logging criteria to be met. The “Stop trigger” operation is similar to that of the “Start Trigger”.
First select whether the trigger is digital or analog by clicking on the appropriate button.
Digital Stopping Triggers
This allows you to stop logging based upon a digital sensor value, e.g. RPM < 200. The first box displays a list of all enabled digital
channels. Select the channel desired or “none”. The third box allows you to select whether the trigger occurs on a rise or fall in the
value «».
The final box allows you to enter the value (e.g. 200). The second box is only used for pure digital signals when you must select whether
the trigger condition is on a high or low value. (The third and fourth boxes do not have any relevance for pure digital signals).
Analog Stopping Triggers
This allows you to stop logging based upon an analog sensor value, e.g. Oil Pressure less than 10.
The first box displays a list of all enabled analog channels. Select the desired or “none”.
The third box allows you to select wether the trigger occurs on a rise or fall in the value. The final box allows you to enter (e.g.10)