![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/35/0353d110-04fd-464d-ab27-64b90992d620/0353d110-04fd-464d-ab27-64b90992d620-bg17.png)
21
Kiosk Modifications of the OLE for Retail POS
Events
11/25/2013 OPOS Driver User Guide P1061668-001 Rev. A
Events
ErrorEvent Event
Remarks Fired when an error is detected and the Control’s State transitions into the error
state.
Input error events are not delivered until the DataEventEnabled property is TRUE, so that
proper application sequencing occurs.
POS Printer Summary
Note • In the Kiosk environment it is not expected that the receipt will be retried because
when a severe Error occurs, a Technician has to go out and clear the Error at the remote
location. Therefore, Retry is not supported and Cancel will clear the printer buffer. All data
will be sent to the printer regardless of the error state.
Table 4 • Common Properties
Property (Common) Ver Type Access May Use After
Zebra Kiosk Printer
Supported
Properties
AutoDisable 1.2 Boolean R/W Not Supported NO
BinaryConversion 1.2 Long R/W Open NO
CapCompareFirmwareVersion 1.9 Boolean R — NO
CapPowerReporting 1.3 Long R Open NO
CapStatisticsReporting 1.8 Boolean R Open NO
CapUpdateFirmware 1.9 Boolean R Open NO
CapUpdateStatistics 1.8 Boolean R Open NO
CheckHealthText 1.0 String R Open NO
Claimed 1.0 BooleanR R Open YES
DataCount 1.2 Long R Not Supported NO
DataEventEnabled 1.0 Boolean R/W Not Supported NO
DeviceEnabled 1.0 Boolean R/W Open & Claim YES
FreezeEvents 1.0 Boolean R/W Open YES
OpenResult 1.5 Long R — YES
OutputID 1.0 Long R Open YES
PowerNotify 1.3 Long R/W Open NO
PowerState 1.3 Long R Open NO
ResultCode 1.0 Long R — YES
ResultCodeExtended 1.0 Long R Open YES
State 1.0 Long R — YES