A SERVICE OF

logo

Page 4-13
Section 4. Electric Checks and Adjustments
SATO CL608e/CL612e Service Manual
PN 9001079
Rev. B
4.9 Ribbon Sensor Operation Verification
1. Flip down the cover on the front panel for access to the dip switches.
2. Record all dip switch positions, then place DSW2-1 in the OFF position and
the power switch OFF.
3. Remove the ribbon from the printer and close the Head Open Lever.
4. Turn the power switch ON to initialize the printer. The following screens
will display.
5. Press the LINE key to place the printer off-line.
6. Press the FEED key. The printer will beep and the following screen will
display to confirm that the ribbon is not in position and confirm the sensor is
functioning.
7. Turn off the printer and reinstall the ribbon.
8. Turn ON the printer. The printer will initialize as in Step 4. Be sure to place
the printer off line. Press the FEED key to generate a blank label and
confirm ribbon has been installed and is in position.
initializing
rom v00.00.00.00
online
qty:000000
Ribbon end
PLACE DSW2-1 IN
THE OFF POSITION
STEP PROCEDURE
SEE PAGE 1-8 FOR
SENSOR LOCATION
No adjustment is provided
for this sensor