Page 4-12
Section 4. Electric Checks and Adjustments
SATO CL608e/CL612e Service Manual
PN 9001079
Rev. B
4.8 Offset Label Stop Position Adjustment
Used for fine adjustment of label stop position for Tear Off, Cutter and Dispense Modes.
The Label Stop Position is adjusted with the Offset potentiometer on the Front Panel.
STEP PROCEDURE
1. Flip down the cover on the front panel for access to the potentiometers.
2. TurnVR2(OFFSET) to the center position.
3. Press the FEED key while simultaneously turning ON the power switch.
4. When the printer beeps, release the key. The following screens will appear.
5. Press the FEED key to display the next screen.
6. Use the LINE Key to step to the second digit of the counter to the desired
setting. The display will increment one step each time the LINE key is
pressed. After the reading will advances to a setting of 09, it will
automatically wrap and start at 10 CM again.
7. Press the FEED key for a test print. Press the FEED key again to stop
printing.
8. Adjust the stop position using VR2 and feed another label. When the
adjustment is correct, turn the printer off. If the print position can't be
adjusted replace the Keyboard PCB. Refer to Section 6.
initializing
rom v00.00.00.00
test print mode
configuration
test print size
10cm
press feed key
to stop printing
Note: The stop position only is
changed with the VR2 (OFFSET).
The print position is changed with
the VR3(PITCH).
The VR2(OFFSET) adjustment range
is +/- 3.75mm.
POTENTIOMETERS ARE LOCATED
UNDERNEATH A FLIP - DOWN COVER
OF THE FRONT PANEL
VR 2