4. In Figure 4-10, the vertical position is correct when both the magenta line and the black line
are aligned (as shown in position OK (0)). If the vertical position is correct, turn off the
printer. If the black and magenta lines are not aligned, perform the vertical adjustment as
described in steps 5-10.
WARNING
The number shown in the sample indicates the thickness level compared to the current
linear spacer. (See * .) There are 11 linear spacers with 11 different thicknesses.
The linear spacer is attached by two pieces, one on each side of the head base. Therefore,
when you need to replace one linear spacer, always replace both linear spacers at the
same time.
When replacing the linear spacer, place it under the angular spacer.
* If necessary, replace the linear spacer. For instance, if your pattern is similar to the pattern
shown under –2, replace the linear spacer with a thinner linear spacer. If your pattern is similar
to the pattern shown under 2, replace the linear spacer with a thicker spacer.
5. Turn the printer off.
6. Move the carriage to the center while pressing the carriage lock lever, and remove the two ink
cartridges.
7. Remove the rubber cap that covering a head screw at the side of color ink cartridge and then
loosen (but do not remove) 3 screws. (Refer to the figure below.)
WARNING
After replacing the spacer, always install new ink cartridges before returning the printer to
the user. During adjustment, use the ink cartridges exclusively for service (Monochrome:
1020626, CMY: 1020627). You can reuse the old ink cartridges for other purposes.
Rubber Cap
Screw 1
Screw 2
Screw 3
Figure 4-10. Removing the Rubber Cap
Adjustments Stylus Pro XL